3 Controller
3-77
Fig.3-28: Specifications for the connection cable
Note 1) The 24V power supply is prepared by customer (The power consumption is approx. 0.3A.)
In the customer's system, do not ground the + side of 24V power supply prepared by customer for connect to
the controller. (related with emergency stop and parallel input/output) If it connects with the controller under
the condition that the + side is grounded, it will lead to failure of controller.
Note 2) The cable for general purpose can be used to the network cable. However, use the twisted shield cable of
AWG#22(0.3mm
2
) or more.
NET cable-1 (Network cable)
Connector: J21DF-06V-KX-L
Connected the frame
ground or protect ground
Connector: 1-178288-3
Connector: 2-178288-3
Pin No.
1
2
3
RIO1/2
TXRXH
TXRXL
SG(GND)
RIO
TXRXDH
TXRXDL
SG(GND)
FG
+
-
Pin No.
1A
1B
2B
3A
DCcable-2 (Power cable)
Pin No.
1
2
3
RIO1/2
24V
24G(RG)
FG(PE)
+24V Power
R-TM (Terminator)
Pin No.
1
2
3
RIO1/2
TXRXH
TXRXL
SG(GND)
100
Ω
List of parts and manufacturer
Type
Connector type
Contact type
Resistant
Manufacturer
NETcable-1
1-178288-3 (2)
1-175218-2 (6)
-
Tyco Electronics
51103-0300 (1)
50351-8100 (3)
-
MOLEX
J21DF-06V-KX-L (1)
SJ2F-01GF-P1.0 (4)
-
JST
DCcable-2
2-178288-3 (1)
1-175218-5 (3)
-
Tyco Electronics
R-TM
1-178288-3 (1)
1-175218-3 (2)
100
Ω
(1/4W) (1)
Equivalent to KOA.