2.Environment & Reliability
Condition
Spec
O
K
N.A
Remark
Operation Temp./Humidity
+5 ~ +40
℃
/ 20~90% R.H.
√
Non-condensing
Non- Operation Temp./Humi.
-20~ +60
℃
/ 10~90% R.H.
√
Non-condensing
Altitude
Operating condition
0~3048m (10,000ft)
√
Without
packing
Non-operating condition
0~12,192m (40,000ft)
√
With
packing
Vibration
1)Sine Wave Vibration
Package, Non-Operating
5 ~ 26.6Hz /0.6g
26.6 ~ 50Hz /0.016”
50~500Hz/ 2.0g
(104 Minutes/Axis for x, y, z)
√
2)Random Vibration
Package, Non-Operating 5 ~ 100Hz, 0 dB/Oct.
0.015g
2
/Hz
100 ~ 200Hz, -6 dB/Oct., -----
200Hz, ------ , 0.0038g
2
/Hz
√
Non-package,
Non-Operating
20Hz~2000/ 0.0185g
2
/Hz
√
Drop (With packing)
Package, Non-Operating
19.4
kg -
61
cm Height
1 corner, 3 edges, 6 faces.
√
Electrostatic Discharge
IEC801-2 standard
Contact:8KV, Air:15KV
√
0.5~8KV tip table no
blanking
Acoustical Noise
< 40 dB/A
√
Power Line Transient
IEC801-4,IEC1000-4-4 Coupling clamp 0 ~ 4KV
√
IEC1000-4-5
(Surge)
Common:2KV,Differential:1KV
√
IEC1000-4-12 (100KHz ringwave)
Common:3KV,Differential:1KV
√
MTBF Demonstration
90% confidence level
> 60,000 Hrs
√
Excluding the CRT
MTBF Prediction
MIL-217F
> 40,000 Hrs
√
Excluding the CRT
CRT Life
78% degradation
> 10000 Hrs
√