Circuit Operation Theory
5
5.2 Blanking CKT
To avoid the disturbed picture display on the screen , we have to blank the monitor in the
following situations.
(1) when display mode is changed.
(2) when the monitor enter the power saving mode.
(3) blank the vertical retrace line
when the " blank" signal becomes "high" Q209 "ON" , Q203 "OFF".G1 voltage is about ( -190 *
R253/(R253+R241))
≒
-184V. The signal which is IC201 (pin 16) is inverted and amplified by Q202,
and coupling to G1.During the vertical retrace interval , the G1 voltage will be drop down about 48V.
Fig5 Brite & Spotkiller circuit