MEA 1786FD2
CRT Monitor Service Guide
Circuit Operation Theory
17
3.7 DEGAUSS CIRCUIT
B59
B56
B60
B55
+12V
2
1
2
1
3
4
+
1
2
D709
M602
C621
RL601
TR602
L604
TR601
D708
D603
D604
D605
R706
R705
C708
Q706
CN602
1N4148
2P
250V
2200P
(Y)
2R9M
180UH
8D-13
1N4148
20D6
20D6
20D6
4.7K
(OPEN)
16V
47U
(EL)
H945
2P
DEGAUSS
This circuit has the function of auto degaussing and manual degaussing. When power supply is
switched ON it is auto degaussing stage. When user make the selection of the manual degaussing
function in OSD, the degaussing current will flow through coil to degauss the screen of monitor.
TR602 is a PTCR to control degaussing coil current
3.8 power saving control
Mode H-sync
V-sync
LED
Power
Rating
Normal Normal Normal Green
100
﹪
Stand-by None
Normal Orange
≦
5W
Suspend Normal None
Orange
≦
5W
Off None
None
Orange
≦
5W
When the H-sync or V-sync are none, the power 6.3v and+13v output will be cut-off.
The power input will be under 5W.