MEA 1786FD2 CRT Monitor Service Guide
Trouble Shooting
3
Case 2: one or more of R, G, B channel does no display
•
Check IC101 pin 18,15,13. If anyone is 0 volt, replace a new IC to IC101.
•
Check RGB cathode. If anyone pin is 0 volt, replace a new IC to IC102.
•
Check IC102 output path. It must be right and without short circuit.
•
Replace CRT if it burns out.
Case 3: OSD does not display on screen
•
Check IC101 pin 1,19,20. If they are 0 volt, check IC101 and IC1901.
Case 4: No video display on screen, but OSD can display on screen
•
Check IC101 pin 10 (Video Contrast). If it is 0 volt, check IC1901 or maybe IC101 pin 10
short.
Case 5: OSD control cannot adjust Bias
•
Check IC1901.
•
Check DC restore circuit.
Case6: OSD control cannot adjust Drive
•
Check IC101 and IC1901.
Case 7: OSD control cannot adjust Contrast
•
Check IC 101 and IC1901.
Case 8: OSD control cannot adjust Brightness
•
Check brightness control circuit (G1) and IC801 BRITE output.
Case 9: ABL cannot adjust
•
Check ABL circuit.
Case 10: Spot killer function failure
•
Check SG101(300KV spark gap). Replace it if it is inserted error.
•
check spot killer circuit.
Case 11: Picture quality is not so good
•
Check CRT socket. Fix it if it is loose.
•
Check IC101 pin 11(clamp gate). If it has no clamping pulse, check H-clamp pulse switch
circuit.
•
Replace IC102.
Case 12: Moire appears when Y is greater than 18 Ft-l
•
Run auto-alignment procedure to acquire optimum G2 voltage.
•
If necessary, decrease G2 voltage.
Case 13: H-blank function failure
Содержание 1786FD2
Страница 17: ...MEA 1786FD2 CRT Monitor Service Guide Engineering Specification 14 21 White x bit9 2 22 White y bit9 2 ...
Страница 19: ...MEA 1786FD2 CRT Monitor Service Guide Engineering Specification 16 47 00 ...
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 93: ......
Страница 94: ......