MEA 1786FD2
CRT Monitor Service Guide
Circuit Operation Theory
12
Switching Power Supply Operation Theory
1. General Specification
Input Voltage : 90~264VAC (FULL RANGE)
Input Frequency : 47~63Hz
Output Requirement:
Output
MAX. Load Current
+6.3V
0.7A
+13V
1.0A
+80V
0.15A
+45V
1.0A
2. Block Diagram
DEGAUSS
CIRCUIT
RFI
FILTER
RECTIFIER
&
FILTER
SWITCHING
ELEMENT
FEEDBACK
CONTROL
CIRCUIT
ISOLATION
TRANSFOR
-MER
POWER
SAVING
CONTROL
OUTPUT
RECTIFIER
AND
FILTER
OUTPUT
AC
INPUT
3. Circuit Operation Theorem
3.1 RFI FILTER
250V
2200P
(Y)
C602
3
4
1
2
L602
250V
2200P
(Y)
C603
L604
L603
250V
0.47U
(X)
C601
N
FG
L
R601
This circuit designed to inhibit electric and magnetic interference for meet FCC, VDE, VCCI standard
requirements.