801 LSV 8 Ton Electric Logsplitter
16
Original Instructions Version August 19
Splitting spar
Before use, the spar of the splitter must be slightly greased. Repeat this procedure every five operating hours. Slightly ap-
ply grease of oil spray. The spar may never run dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil pump and control valve. The system is complete when the machine
is delivered, and may not be changed or manipulated.
Connections and repairs
Connections and repairs of electrical equipment may only be carried out by an electrician.
Service information
Please note that the following parts of this product are subject to normal or natural wear and that the following parts are
therefore also required for use as consumables. Wear parts*: splitting wedge guides, hydraulic oil, splitting wedge
* Not necessarily included in the scope of delivery!
15. Troubleshooting
The table below contains a list of error symptoms and explains what you can do to solve the problem if your tool fails to
work properly. If the problem persists after working through the list, please contact your nearest service workshop
.
16. Disposal and recycling
The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging
can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and
plastic. Defective components must be disposed of as special waste. Ask your dealer or your local council.
Malfunction
Possible cause
Remedy
The hydraulic pump does not
start
No electric power
Check cable for electric power
Thermal switch of motor cut off
Engage thermal switch inside the motor casing
again
The column does not move
down
Low oil level
Check oil level and refill
One of the levers not connected
Check fixing of lever
Dirt in the rails
Clean the column
Motor starts but column does
not move down
Wrong turning direction of 3-phase
motor
Check turning direction of motor and change