Technician’s Handbook
10
n
LIGHTWARE 17 supports one digital bay with two T1 trunk cards
and the other digital bays with one T1 trunk card to total a max of 7.
n
If a T1 trunk card is installed in slot 10 of a bay, you cannot install a
peripheral interface cards in slot 5; if a T1 trunk card is installed in
slot 11, you cannot install a peripheral interface card in slot 6. T1
cards in slots 10 and 11 are seen by the software as slots 5 and 6.
n
The two T1 links from the T1/E1 module on a BCC III card also
occupy slots (in software) 5 and 6. The BCC III only supports one
T1/E1 module.
n
The BRI card is a low power peripheral interface card (slots 1-8) and
requires a BCC III in the same SX-200 ELx cabinet. If the BRI card
is in a control cabinet, the BCCIII must have a Maintenance module.
A cabinet holds a maximum of two BRI cards.
n
You can have one PRI card in a main control cabinet; up to two in a
peripheral cabinet. PRI cards are installed in slots 10 or 11 in the
SX-200 ELx cabinet Rev 4.4 or greater (PN 9109-600-002-NA ). The
PRI card requires a Statum 3 MCC. The system counts the PRI card
as a peripheral bay.
n
If a PRI card is installed in slot 10, you can install a peripheral
interface card in slot 5; if a PRI card is installed in slot 11, you can
install a peripheral interface card in slot 6. Because the system
recognizes the PRI card as a peripheral bay, the PRI card does not
occupy slots (in software) 5 or 6 in the bay that the card sits in.
n
LIGHTWARE 18 and greater allows a maximum of 4 high power
cards in any of the slots 1 through 8 (there are no high/low power
slots).High power cards are DID, Universal, COV and T1.
Low power cards are DNIC, OPS, ONS, BRI, LS/CLASS, and
LS/GS.Unlike the T1 card, the PRI card is a separate bay and is not
included in the count for the 4 high power cards.
If the cabinet has a BCC II, do not install more than seven
DNICs per bay in high traffic applications. If you have more
than seven DNICs per bay keep the device count to 84 or
less. With two T1 cards in a bay, do not add more than five
DNICs or 60 devices. With one T1 card in a bay, do not add
more than six DNICs or 72 devices.If the cabinet has a BCC
III, you can install eight DNICs per bay.
Содержание SX-200 EL
Страница 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Страница 11: ...Chapter 1 Introduction ...
Страница 12: ......
Страница 32: ...Technician s Handbook 22 ...
Страница 33: ...Chapter 2 Routine Maintenance ...
Страница 34: ......
Страница 55: ...Chapter 3 Troubleshooting and Repair ...
Страница 56: ...Technician s Handbook 46 ...
Страница 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Страница 110: ...Technician s Handbook 100 ...
Страница 111: ...Chapter 4 Programming ...
Страница 112: ......
Страница 168: ...Technician s Handbook 158 ...
Страница 169: ...Chapter 5 Installation ...
Страница 170: ......
Страница 175: ...Installation 165 Installation SX 200 ML FD Cabinet Card Assignment Figure 24 SX 200 ML FD Cabinet Card Assignment ...
Страница 176: ...Technician s Handbook 166 SX 200 LIGHT Cabinet Card Assignment Figure 25 SX 200 LIGHT Cabinet Card Assignment ...
Страница 239: ...Chapter 6 Maintenance Commands ...
Страница 240: ......
Страница 258: ...Technician s Handbook 248 ...
Страница 261: ...Notes ...
Страница 262: ...Technician s Handbook Notes ...