112
5.5.4
Other OEM Command Set
Restore Factory Default Command
Net Function =
32h (OEM)
Code
Command
Request, Response Data
Description
66h
Restore Factory Default
Request:
NA
Respones:
Byte 1 – Completion code.
When send this command to BMC, the LAN Configuration Parameters
will be changed current setting value to default value as following:
1.
IP Address Source = 0x00(DHCP)
2.
The Network sequence priority default is Mezzanine card for
PVT/MP.
3.
The MEZZ protocol priority default is NCSI for PVT/MP.
4.
User IDs
(User/Password/Privilege/Channels).
5.
Debug Console Serial Parameters.
6.
Product Information
- Product ID.
- Manufacturer ID
Remove all the special settings such as different priority, but SEL will
not remove.
(Note: The BMC will reset itself after restore to default.)
Get 80 Port Record Command
Net Function = 30h (OEM)
Code
Command
Request, Response Data
Description
49h
Get 80 Port Record
Request: N/A
Response:
Byte 1 – Completion code.
Byte 2:N – POST code.
Replay the last port 80 POST codes
(up to 256x POST records).
N: maximum number = 256
Get CPLD Information Command
Net Function =
3Ch (OEM)
Code
Command
Request/ Response Data
Description
88h
Get CPLD Information
Request: N/A
Response:
Byte 1 – Completion code.
Byte 2 – CPLD version number.
Byte 3:6 – Device ID(LSB first).
Byte 7:10 – Checksum(LSB first).
1.
Get CPLD version via
CPLD SGPIO by
BMC.
2.
Get CPLD Device ID
via JTAG interface
by BMC.
Содержание E8020
Страница 1: ...E8020 OCP Computing Sled User Manual Version 1 0 ...
Страница 7: ...2 APPENDIX A 124 ...
Страница 12: ...7 2 1 2 Ultra Note 4x U 2 drives One FHHL PCIe card ...
Страница 29: ...24 2 2 5 Release the Drive A Pull the locking Drive lever open in the direction of arrow B Take out Drive ...
Страница 32: ...27 B Push the Right Left handle bar to lock the Drive Cage ...
Страница 33: ...28 C Insert the Riser Card ...
Страница 34: ...29 D Fasten the latch to lock the riser card E Open the retainer as shown ...
Страница 36: ...31 3 Mainboard Information 3 1 Board Introduction Here are different views of the main board ...
Страница 39: ...34 3 4 Block Diagram ...
Страница 47: ...42 CPU 0 Information ...
Страница 50: ...45 4 3 4 Serial Port Console Redirection ...
Страница 54: ...49 Console Redirection Settings COM1 ...
Страница 62: ...57 4 3 7 USB Configuration ...
Страница 73: ...68 Socket 0 Information View Information related to Socket 0 ...
Страница 94: ...89 4 9 Save Exit ...
Страница 127: ...122 Here is the example of OOB BIOS update IP Your BMC IP C439_TGPSNTT_101 BIN The BMC image you received ...
Страница 128: ...123 6 2 2 BMC update You can do BMC update via local or OOB Example of local BMC update Example of BMC update via OOB ...