LCD Status Messages
13
Viewing Status Messages
If a system error occurs, the LCD screen turns amber. Press the
Select
button to view
the list of errors or status messages. Use the left and right arrow buttons to highlight
an error number, and press
Select
to view the error.
Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the
LCD message is automatically removed when that sensor returns to a normal state.
For other faults, you must take action to remove the message from the display:
◆
Clear the SEL—You can perform this task remotely, but you lose the event
history for the appliance.
◆
Power cycle—Power off the appliance and disconnect it from the electrical
outlet; wait approximately ten seconds, reconnect the power cable, and restart
the appliance.
The following LCD status messages are displayed in the Simple format. For more
information about selecting the format in which the messages are displayed, see
Table 4
LCD Status Messages
Code
Text
Cause
Corrective Actions
E1000
Failsafe voltage error.
Contact support.
Check the appliance
event log for critical
failure events.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
If the problem persists,
see
E1114
Ambient Temp exceeds
allowed range.
Ambient temperature has
a reached a point outside
of the allowed range.
See
E1116
Memory disabled,
temp above range.
Power cycle AC.
Memory has exceeded
allowable temperature
and has been disabled to
prevent damage to the
components.
Remove AC power to
the appliance for 10
seconds and restart the
appliance.
See
on page 75. If
the problem persists,
see
E1210
Motherboard battery
failure. Check battery.
CMOS battery is missing
or the voltage is outside
of the allowable range.
See
Содержание RazorSafe 700
Страница 10: ...4 Preface ...
Страница 32: ...About Your Appliance 26 1 ...
Страница 96: ...Jumpers and Connectors 90 B ...