58
Peripheral Equipment
Web Interface
2
• The
0 dBFS level
parameters are available for an ABT with analog inputs. They allow the adjustment
of the 0 dBFS level for each input. The number of inputs depends on the model. In the case where all
inputs must be set to the same level, click
Yes
beside
Set all levels using CH 1
.
The changes take effect when you click
Apply
.
Finally, factory default values for all parameters on this page can be displayed by clicking
Factory
Defaults
.
The Audio level adjustments are not applicable to ABT models with digital inputs and do not appear on the
Web page.
Network Configuration Web Page
Network Configuration Web page
The Network Configuration page allows you to configure network parameters.
The
MAC address
is the unique hardware address attributed to each Audio Bridge Terminal unit. Each unit
has a different address, this being the only way to distinguish the units from each other when connected
to a network.
The
Label
parameter gives the unit a label. The label is found in the title of the Web page. It can contain
up to 16 characters. Valid characters are from the English alphabet (lowercase a through z, uppercase
A through Z), numbers 0 through 9, the hyphen (-), the underscore (_) and the asterisk (*). If an invalid
character is used, an error message will appear. The same label can be used by many units.
The
DHCP
parameter activates or deactivates dynamic network addressing. When activated, it allows a
server to dynamically attribute an IP address and configuration information to the Audio Bridge Terminal.
Note:
If changes to parameters are made before clicking
Apply
and the user wishes to
reestablish the values displayed when the page was loaded, this can be done by clicking
Cancel Changes
.