13
1079321-W2-G
Warning!
installations have been completed.
1.
Decide on a suitable location for
the shower unit
avoiding buried
cables and pipes
. The unit should be
positioned at a height convenient for
all the family (at least 200 mm below
removal of the unit cover).
The handset should spray away from
the shower unit, either down the
centre line of the bath or across the
shower cubicle opening. Make sure
when the hose retaining ring is placed
on the lowest position on the slide bar,
the handset does not fall below the
minimum clearance gap
, between
the bath or shower tray spillover level
of 25 mm.
2.
Hot and cold inlet supply connections
are:
Hot – Left
Cold – Right
Run the hot and cold water supply
pipes at 28 mm centres, make sure
that the pipe ends project 30 mm into
the inlet manifold.
Warning!
Supply connections
must
not
be connected in reverse.
Caution! Do not
use stainless steel
piping for inlet pipework.
Caution!
If the pipework is chrome
plated remove all traces of chrome
from the connecting surfaces. If the
chrome is not removed then the
inlet manifold collets will
not
grip the
supply pipe.
H
C
Do not fix the shower unit to the wall until plumbing and electrical
the ceiling to allow for the fitting and
3.
Make sure that the end of the supply
pipework is cut squarely and is
free
from burrs
, which will damage the
inlet manifold seals.
Chamfer the end of the pipe to assist
the ‘O’ seal tearing.
Warning!
Do not
result in injury.
Caution!
Thoroughly flush the
incoming hot and cold water supply
pipes to remove debris before
connecting the shower unit.
4.
Run the electrical supply cable in
surface mounted miniature trunking
to connect to the terminal block
(approximately 275 mm). Strip back
approximately 30 mm of outer cable
insulation.
5.
Loosen the three cover securing
screws and remove the shower unit
cover.
Note!
The cover securing screws
are captive and should
not
be
unscrewed fully from the unit case.
6.
Insert the push-fit release tool
plug and the inlet manifold collet
and lever the plugs outward. Whilst
holding back on the collet, pull out
the appropriate blanking plug by
hand.
insertion into the fitting and prevent
the push-fit connectors as this can
(not supplied). Allow sufficient cable
between the flange of the blanking
insert fingers into
Chamfer
Trim the thinned section of
the case covering the cable
channel.
Push-fit
Release Tool
Blanking Plug
Inlet Manifold
Collet
Securing
Screws
Securing Screw
Содержание 1.1532.327