Tank Level Inputs
The tank level connector provides field connection points for external floats, the dry contact
outputs on a tank level controller, or the dry contact outputs of a plant PLC or other control
device. Tables 1 and 2 provide descriptions for each terminal.
Table 1 Tank Level Connector Name and Description
Connection Name
Signal Description
TLSL1
Lower tank level input 24VDC-CLOSED 0VDC-OPEN
TLSL2
+24VDC source of lower tank level input
TLSH1
Upper tank level input 24VDC-CLOSED 0VDC-OPEN
TLSH2
+24VDC source of upper tank level input
Table 2 Tank Level Status
INPUT STATES
SYSTEM
Lower Level Input
Upper Level Input
System Action
Closed
Closed
Tank is empty - Turn ON
Open
Open
Tank is full - Turn OFF
Open
Closed
Stand-by - Stays Off or ON
Closed
Open
Fault Condition - Turn OFF
Figure 9 Tank Level Connector