11
4. In order to locate the terminal block on the battery pack you will need
to remove the top cover of the battery pack. Note: On some models,
the terminal block may be accessed from the rear panel of the
battery pack.
Warning: When the cover is removed, danger of shock exists from
the batteries. Use extreme caution.
5. Connect the positive connection of the battery pack to the positive
connection on the UPS. Connect the negative connection of the
battery pack to the negative connection on the UPS. Carefully
verify that the polarity is correct. Not all battery packs are
provided with connection wires. If your battery pack is not provided
with wires, you must use 8 gauge wire for these connections. A third
wire may be connected from chassis to chassis to provide a safety
ground for the battery pack case (not required).
6. After all connections have been made and verified to be correct,
reinstall the cover on the battery pack if it was removed. Insure all
cover screws are installed.