50 (2181)
REP
AIR GUIDE
Save flash ROM data of master body (Mass production camera body of #2181), which is used for adjustment
of CCD ceter position and adjustment of white balance, to PC.
If flash ROM data of master body is over written by mistake, load flash ROM data from PC and re-write
flash ROM data of master body.
Caution: Exchange Master body for new 2181 body at every 5000 times shutter release to keep accuracy of
adjustment.
Required equipment
PC with preinstalled the 2181 adjustment program
CF card for Adjustment
AC Adapter AC-11
USB-2 (USB cable)
* Use the AC adapter (AC-11) not batteries when adjusting.
Save Flash ROM data of Master Body to PC.
Caution: Peform this operation at every time you register Master Body.
1. Click SAVE , left side of PAST in adjustment menu.
2. Save data to anywhere with any name you like.
For Example
Save location: 2181ADJ folder on Desktop of PC
File name: MASTER_DATA
If you use the file name above, the real file name of saved data is MASTER_DATA2181 .
3. Click SAVE , message below is displayed and saving data is complete.
The adjustment data save has completed!
Load Flash ROM data to Master Body from PC
Peform this operation, if flash ROM data of master body is over written by mistake.
1. Click PAST , right side of SAVE in adjustment menu.
2. Select saved flash ROM data.
For Example
Saved location: 2181ADJ folder on Desktop of PC
File name: MASTER_DATA2181
3. Click Open , message below is displayed and pasting data is complete.
The adjustment data copy has completed!
Back up Flash ROM data of Master Body
Содержание DYNAX 7