FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-80
(6)
IR System: incorrect color image registration, sync shift (lines in CD)
<Typical Faulty Image>
<Troubleshooting Procedure>
Section
Step
Check Item
Result
Action
Original
1
Original does not lie flat.
YES
Change original.
Original
Cover
2
Original Cover does not lie flat.
YES
Change Original Cover if it is
deformed or hinges are bro-
ken.
Slide rails
3
Foreign matter on rails.
YES
Clean and apply lubricant.
Drive
Cables
4
Cable kinks or is damaged.
YES
Correct or change.
Scanner
Assy
5
Scanner moves smoothly.
NO
Adjust the Scanner Motor tim-
ing belt.
→
Change bushing.
→
Change Scanner Motor.
6
The problem has been elimi-
nated through the checks of
steps up to 5.
NO
Change CCD Unit.
C F
C F
4011T039AA