FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-92
Image Transfer
Belt Unit
12
Image Transfer Belt Unit
makes positive contact
with plates on rails.
NO
Check and correct contacts.
13
Cam gear operates
properly.
NO
Change Image Transfer Belt
Unit.
Hopper Unit
14
Connectors are loose.
YES
Reconnect.
15
Gear is cracked.
YES
Change gear.
16
Toner empty lever and/or
detecting switch are
defective.
YES
Change Hopper Unit.
Gradation Adjust
(Tech. Rep. Mode)
17
“Conv. Value” falls within
the specified range as
checked through Grada-
tion Adjust.
Max: 0 ±100
Highlight = 0 ±60
NO
Go to step 21.
Image Adjust
→
PRT Max Den-
sity (Tech.
Rep.Mode)
18
The problem has been
eliminated through the
adjust of PRT Max.
NO
Go to next step.
Image Adjust
→
PRT Highlight
(Tech. Rep. Mode)
19
The problem has been
eliminated through the
adjust of PRT Highlight.
NO
Go to next step.
Image Adjust
→
Stabilizer
→
Reset + Stabilizer
(Tech. Rep. Mode)
20
After the Reset + Stabi-
lizer sequence has been
completed, run Grada-
tion Adjust; if the prob-
lem persists, make
adjustments of PRT Max
Density and PRT High-
light.
NO
Go to next step.
21
The problem has been
eliminated through the
checks of steps up to 20.
NO
Change IU.
→
Change Image Transfer
Belt Unit.
→
Change LPH Assy.
→
Change PIC Board.
→
Change LED Drive Board.
→
Change LPH Unit.
→
Change High Voltage Unit
(Developing Bias).
→
Change High Voltage Unit
(Image Transfer, Neutraliz-
ing).
Section
Step
Check Item
Result
Action
Содержание CF2002
Страница 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Страница 2: ......
Страница 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Страница 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Страница 58: ...FrameMaker Ver 5 5E PC CF2002 CF3102 DIS REASSEMBLY ADJUSTMENT 02 06 26 DIS REASSEMBLY ADJUSTMENT 14413 ...
Страница 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...