FrameMaker Ver5.5E(PC) CF3102/CF2002 SWITCHES ON PWBs/TECH. REP. SETTINGS
02.06.05
S-33
State Confirm
Item
Purpose
Setting/Precautions
I/O Check
To display the states of the
input ports of sensors and
switches when the copier
remains stationary.
Used for troubleshooting
when a malfunction or a
misfeed occurs.
• The operation of each of the switches and
sensors can be checked on a real-time
basis.
• It can be checked as long as the 5-V
power line remains intact even when a
cover is open.
Table #
To display the Vg/Vb out-
put values calculated for
the image density of the
test pattern (amount of
toner sticking) produced on
the Transfer Belt during an
AIDC detection sequence.
Used for troubleshooting
of image problems.
• Reference values
C, M, Y .. Vb: around 400 V
Vg: around 550 V
The higher the humidity, the lower these
values, and the lower the humidity, the
higher these values.
Level History 1
To display ATDC (T/C ratio),
AIDC/Regist Sensor output
values, and fusing tempera-
ture.
Used for troubleshooting
of image problems.
• AIDC: Shows the AIDC bare surface out-
put reading taken last.
• ATDC, fusing temperature: Shows the lat-
est ATDC and fusing temperature data.
<“Reading taken last” means>
• After the last image stabilization
sequence.
• When a test print is produced by pressing
the Start key while Level History 1 is
being displayed.
Level History 2
To display the intensity
adjustment value of the
AIDC Sensor (Transfer Belt
bare surface level) as
adjusted through the image
stabilization sequence and
ATVC value.
Used for troubleshooting
of image problems.
• AIDC Sensor: Shows the intensity adjust-
ment value (0 to 255) of the AIDC Sensor.
• ATVC (C, M, Y, Bk): Shows the first image
transfer ATVC adjustment value (400 V to
3000 V).
• ATVC (2nd): Shows the second image
transfer ATVC adjustment value (300 V to
5000 V).
Temp. &
Humidity
To display the temperature
and humidity of a specific
location (AIDC Sensor por-
tion) inside the copier and
fusing temperature.
Used as reference infor-
mation when a malfunc-
tion occurs.
• Copier interior temperature: 0 to 100
°
C
in 1
°
C increments
• Temperature on Fusing Belt side: 0 to 255
°
C in 1
°
C increments
• Temperature on fusing pressure side: 0 to
255
°
C in 1
°
C increments
• Copier interior humidity: 0 to 100% in 1%
increments
• Absolute humidity: 0 to 100 g/cm3 in 1-g/
cm3 increments
Содержание CF2002
Страница 1: ...The essentials of imaging www minoltaeurope com Service Manual CF2002 CF3102 ...
Страница 2: ......
Страница 21: ...FrameMaker Ver 5 5E PC CF2002 CF3102 GENERAL 02 06 26 GENERAL 14413 ...
Страница 30: ...FrameMaker Ver 5 5E PC CF2002 CF3102 MAINTENANCE 02 06 26 MAINTENANCE 14413 ...
Страница 58: ...FrameMaker Ver 5 5E PC CF2002 CF3102 DIS REASSEMBLY ADJUSTMENT 02 06 26 DIS REASSEMBLY ADJUSTMENT 14413 ...
Страница 178: ...FrameMaker Ver 5 5E PC CF2002 CF3102 TROUBLESHOOTING 02 06 26 TROUBLESHOOTING 14413 ...