![Minolta CF1501 Скачать руководство пользователя страница 150](http://html.mh-extra.com/html/minolta/cf1501/cf1501_service-manual_1802906150.webp)
FrameMaker Ver.5.5E(PC) CF1501/CF2001 DIS/REASSEMBLY, ADJUSTMENT
00.12.25
D-18
2-4.
Guidelines for Life Specifications Values by Unit
NOTES
• The life specifications values represent the number of copies made or figures equivalent
to it when given conditions are met. They can be more or less depending on the copier
operating conditions of each individual user.
• The initiation of a new copy cycle is inhibited upon 1 K after a near life condition has
been detected for all units (except the Toner Bottle and Waste Toner Bottle).
M: minutes
Unit
Life
Spec.
Value
Copying
Condition
Description
Near Life
Value
Life Value
Toner Bottle
—
B/E
An approximate life value is 10 K
under the specified conditions.
—
10 K
Waste Toner
Bottle
40 K
B/C/D/E/F
A waste toner full condition is
detected when about 4.5 K copies
are made after a waste toner near-
full condition has been detected.
—
40 K
Fusing Web
Unit
17 K
B/C/D/F
The life specifications value is
based on A4C or Letter C. A near
life condition is detected when a
web empty condition is detected or
a predetermined number of copies
are made, whichever arrives ear-
lier.
16 K
17 K
20-cpm copier
Oil Coating
Unit
33 K
A/B/C/D/F
The life specifications value is
based on A4C or Letter C. A near
life condition or a life condition is
detected when the Oil Coating
Roller has turned a predetermined
period of time or a predetermined
number of copies are made, which-
ever arrives earlier.
33 K
34 K
15-cpm copier
Oil Coating
Unit
26 K
26 K
27 K
Fusing Unit
101 K
B/C/D/F
The life specifications value is
based on A4C or Letter C.
101 K
✽
1 102 K
Transfer Belt
Unit
120 K
A/B/C/D/F
The life specifications value is
based on A4C or Letter C.
✽
2
120 K
(17400 M)
✽
2
121 K
(17545 M)
20-cpm copier
Imaging Unit
(C, M, and Y)
30 K
A/B/C/D/F
The near life and life time values
are detected when the PC Drum
has turned or the Developing Unit
has been energized for a predeter-
mined period of time, whichever
arrives earlier.
✽
3
4415 M
(30 K)
✽
3
4562 M
(31 K)
15-cpm copier
Imaging Unit
(C, M, and Y)
27 K
✽
3
4415 M
(27 K)
✽
3
4562 M
(28 K)
20-cpm copier
Imaging Unit
(Bk)
50 K
✽
3
6972 M
(50 K)
✽
3
7122 M
(51 K)
15-cpm copier
Imaging Unit
(Bk)
47 K
✽
3
6972 M
(47 K)
✽
3
7122 M
(48 K)