miniDSP Ltd, Hong Kong /
www.minidsp.com
/ Features and specifications subject to change without prior notice
17
3.2
C
ONNECTIONS FOR ACOUSTIC MEASUREMENT
The figure below shows a typical connection diagram for performing acoustic measurement. No changes to the
existing HDMI connections are needed. Simply:
1.
Connect the supplied USB (type A to type B) cable from the nanoAVR DL to a USB port on the computer.
2.
Connect the supplied USB (type A to mini type B) cable from the UMIK-1 to a USB port on the computer.
Place the UMIK-1 microphone into a microphone stand and position the computer and cabling so that there is
enough freedom of movement to move the microphone into the needed locations. A small tripod stand is
supplied with the UMIK-1, but a larger stand with boom arm can be used if desired. We recommend that the
microphone be oriented vertically (pointed at the floor or ceiling) and the “90 degree” calibration file used (see
Mic Config tab
below).