PRELIMINARY
miniDSP Ltd, Hong Kong /
www.minidsp.com
/ Features and specifications subject to change without prior notice
49
6.2
D
ESIGNING YOUR TARGET CURVE
The
target curve
is the desired magnitude response with the
C-DSP 8x12 DL
processor performing digital room
correction.
6.2.1
The Auto Target
When first viewing the
Filter Design
tab, an estimated target curve suitable for your speakers is shown as the
red curve. This calculated target curve can be restored at any time by clicking on the
Auto Target
button.
Note: restoring the auto target will erase the current target curve. If you wish to keep it, you can save it to a file
–
see
Saving and loading target curves
on page 51.
6.2.2
Editing the target curve
You can edit the target curve to produce any desired magnitude response. This is done with the use of
anchor
points
, shown as orange dots on the curve:
•
Drag an anchor point to move it.
•
Double-click on the target curve to add an anchor point.
•
Double-click on an anchor point to delete it.
The regions to the left and right of the response graphs that are shaded in a darker color are excluded from
magnitude response correction. You can adjust the frequency range for your system and preferences. For
example, low-frequency noise (traffic, machinery) may be present when measuring, so it is best to adjust the
frequency range to exclude these frequencies from the correction. Or, you can experiment with the upper
curtain to see whether you prefer full-range correction or correction over a limited region.