background image

3) Make sure that the purple jet

is properly installed inside
the medicine cup. (The stem
inside the medicine cup
inserts into the tube of the
purple jet),

Fig. 4

.

4) Add the prescribed

amount of medication
to the medication cup,

Fig. 5

.

5) Reassemble the Nebulizer

by carefully twisting the
medicine cup and cover
together. Make sure that
the two parts fit securely.

Operating Your Nebulizer

NOTE:

The Nebulizer is operable at up to a

45

°

angle.

1) Attach one end of the

air tube to the air tube
connector,

Fig. 6

.

2) Carefully attach the

opposite end of the air
tube to the stem at the
base of the Nebulizer,

Fig. 7

.

3) Attach the angled mouthpiece

or optional mask to the top of
the Nebulizer,

Fig. 8.

If using the optional tee
adapter set,

a) Attach the tee adapter to

the top of the Nebulizer,

b) Connect one end of the

tee adapter to the straight
mouthpiece and the other
to the extension tube.

NOTE:

The tee adapter is

not needed when using a
mask.

4) Check that the POWER

switch is in the ‘off’
position. Plug the power
cord into a main outlet.

5) Press the POWER switch

to the ‘on’ position.

6) Start your treatment according to your

physician’s or therapist’s instructions.

NOTE:

The crescent-

shaped groove on
the handle of the
compressor can be
used to support the
nebulizer during
treatments,

Fig. 9

.

7) Once the treatment

is complete, press
the POWER switch to the ‘off’ position
and unplug the power cord from the
outlet.

IMPORTANT!

The compressor will automatically shut off if
it becomes overheated. If/when this
happens, immediately:

1) Press the POWER switch to the ‘off’

position.

2) Unplug the power cord from the outlet.
3) Allow the motor to cool for 30 minutes.

Before restarting the unit, make sure that
the air vents are not obstructed.

After Every Use

1) Unplug the unit from the power source.
2) Allow the unit to completely cool.
3) Carefully detach the air tubing from the

Nebulizer and pour out any remaining
medication.

4) Follow the cleaning procedures provided

in this guidebook.

5

Fig. 4

Fig. 5

Fig. 9

Fig. 7

Fig. 8

Fig. 6

Содержание 40-125-000

Страница 1: ...an aerosolized medication is required during therapy Please consult with your physician and or pharmacist to determine if your prescription medication is approved for use with this Nebulizer This Neb...

Страница 2: ...limitation may not apply to you This warranty constitutes MABIS only responsibility and obligation to repair and or replace materials or components or refund the purchase price MABIS will not be respo...

Страница 3: ...ould not be left unattended while plugged in Do not tilt or shake the unit when in operation Disconnect the unit from the electrical outlet before cleaning filling and after each use Do not use attach...

Страница 4: ...ee parts distilled water 4 Submerge the rinsed parts in the vine gar distilled water solution for 30 minutes 5 Follow steps 4 6 under Rinsing Technique Cleaning the Compressor Wipe the compressor dail...

Страница 5: ...r is not needed when using a mask 4 Check that the POWER switch is in the off position Plug the power cord into a main outlet 5 Press the POWER switch to the on position 6 Start your treatment accordi...

Страница 6: ...in the Nebulizer of misting cup Check the Nebulizer for damage Check the position of the purple jet inside the Nebulizer Make sure that air tube and other components are properly attached Check the ai...

Страница 7: ...bulizer Air Tube Angled Mouthpiece five 5 Air Filters Optional Accessories Angled mouthpiece kit Tee adapter set Baby Pacifier Inhaler set Child Mask Adult Mask Child s Dragon Mask Air Filters Carryin...

Страница 8: ...8 NOTES...

Страница 9: ...repiratorias en las cuales se requiere un medicamento en aerosol durante la terapia Consulte con su m dico y o farmac utico para determinar si el medicamento recetado ha sido aprobado para usarse con...

Страница 10: ...eparaciones 1931 Norman Drive South Waukegan IL 60085 Al devolver un producto tambi n incluya por favor una carta con su nombre direccion numero de tel fono y una breve descripci n del problema especi...

Страница 11: ...ada o reparada No deje la unidad desatendida mientras est enchufada No incline ni sacuda la unidad mientras est en funcionamiento Desconecte la unidad del tomacorriente el ctrico antes de limpiarla ll...

Страница 12: ...t en la posi ci n de apagado off antes de limpiar armar y antes o despu s de cada uso Desconecte la unidad del tomacorriente el ctrico previo a la limpieza Limpie todas las partes necesarias despu s d...

Страница 13: ...a un juego de adaptador en T opcional a Conecte el adaptador en T a la parte superior del Nebulizador b Conecte un extremo del adaptador en T a la pipeta recta y el otro al tubo de extensi n NOTA El a...

Страница 14: ...e se acciona el interruptor de ENCENDIDO No se produce Verifique que haya o se forma medicamento en el vaso poca niebla del Nebulizador Verifique que el Nebulizador no est da ado Verifique la posici n...

Страница 15: ...bulizador Manguera de Conexi n Pipeta Curva Filtros de Aire 5 Accesorios Opcionales Boquilla con ngulo Av os Juego de Adaptador en T Juego de Inhalador con Chupete para Beb s M scara para Ni os M scar...

Страница 16: ...16 NOTAS...

Отзывы: