Product Identification

Cautions

Product Cautions

Please use general safety precautions when
operating your Nebulizer.

This unit should be used only for (1) its
intended purpose as described in this
guidebook, and (2) with medications only
under the supervision and instruction of your
physician.

READ THE FOLLOWING BEFORE USING

• To avoid electrical shock: Keep unit away

from water • Do not handle the unit or
power cord with wet hands • Do not
immerse the unit in liquid • Do not use
while bathing • Do not reach for a unit that
has fallen into water – immediately unplug
the unit.

• Do not use the unit if it has any damaged

parts (including power cord or plug), if it
has been submersed in water or dropped.
Promptly send the unit for examination
and repair.

• The unit should not be used where

flammable gas, oxygen or aerosol spray
products are being used.

• Keep the air vents open. Do not place the

unit on a soft surface where the openings
can be blocked.

• If the medicine cup is empty, do not

attempt to operate the unit.

• If any abnormality occurs, discontinue use

until the unit has been examined and
repaired.

• The unit should not be left unattended

while plugged in.

• Do not tilt or shake the unit when in

operation.

• Disconnect the unit from the electrical

outlet before cleaning, filling and after
each use.

• Do not use attachments unless

recommended by the manufacturer.

Operating Cautions

• Close adult supervision is highly

recommended when this unit is used by
children or invalids.

• Keep your eyes away from the output of

medication mist.

• The maximum capacity of the medicine

cup is 13cc and should not be overfilled.

• Do not use this unit while operating a

vehicle.

• If any discomfort or abnormality occurs,

stop using the unit immediately.

Storage Cautions

• Do not store the unit in direct sunlight,

high temperature or humidity.

• Keep the unit out of reach of small

children.

• Always keep the unit unplugged while not

in use.

Cleaning Cautions

• Check the air filter, Nebulizer, mouthpiece,

and any other optional components before
each use.
Dirty or worn parts should be replaced.

• Do not immerse the unit in water. It may

damage the unit.

• Disconnect the unit from the electrical

outlet before cleaning.

• Clean all necessary parts after each use

as instructed in this guidebook.

3

Compressor

Handle

Angled Mouthpiece

Air Tube

Power Cord

POWER
Switch

Air

Vents

Air Filter
& Cover

Air Tube
Connector

a) Cover

b) Purple Jet

c) Medicine Cup

Nebulizer

Содержание 40-125-000

Страница 1: ...an aerosolized medication is required during therapy Please consult with your physician and or pharmacist to determine if your prescription medication is approved for use with this Nebulizer This Neb...

Страница 2: ...limitation may not apply to you This warranty constitutes MABIS only responsibility and obligation to repair and or replace materials or components or refund the purchase price MABIS will not be respo...

Страница 3: ...ould not be left unattended while plugged in Do not tilt or shake the unit when in operation Disconnect the unit from the electrical outlet before cleaning filling and after each use Do not use attach...

Страница 4: ...ee parts distilled water 4 Submerge the rinsed parts in the vine gar distilled water solution for 30 minutes 5 Follow steps 4 6 under Rinsing Technique Cleaning the Compressor Wipe the compressor dail...

Страница 5: ...r is not needed when using a mask 4 Check that the POWER switch is in the off position Plug the power cord into a main outlet 5 Press the POWER switch to the on position 6 Start your treatment accordi...

Страница 6: ...in the Nebulizer of misting cup Check the Nebulizer for damage Check the position of the purple jet inside the Nebulizer Make sure that air tube and other components are properly attached Check the ai...

Страница 7: ...bulizer Air Tube Angled Mouthpiece five 5 Air Filters Optional Accessories Angled mouthpiece kit Tee adapter set Baby Pacifier Inhaler set Child Mask Adult Mask Child s Dragon Mask Air Filters Carryin...

Страница 8: ...8 NOTES...

Страница 9: ...repiratorias en las cuales se requiere un medicamento en aerosol durante la terapia Consulte con su m dico y o farmac utico para determinar si el medicamento recetado ha sido aprobado para usarse con...

Страница 10: ...eparaciones 1931 Norman Drive South Waukegan IL 60085 Al devolver un producto tambi n incluya por favor una carta con su nombre direccion numero de tel fono y una breve descripci n del problema especi...

Страница 11: ...ada o reparada No deje la unidad desatendida mientras est enchufada No incline ni sacuda la unidad mientras est en funcionamiento Desconecte la unidad del tomacorriente el ctrico antes de limpiarla ll...

Страница 12: ...t en la posi ci n de apagado off antes de limpiar armar y antes o despu s de cada uso Desconecte la unidad del tomacorriente el ctrico previo a la limpieza Limpie todas las partes necesarias despu s d...

Страница 13: ...a un juego de adaptador en T opcional a Conecte el adaptador en T a la parte superior del Nebulizador b Conecte un extremo del adaptador en T a la pipeta recta y el otro al tubo de extensi n NOTA El a...

Страница 14: ...e se acciona el interruptor de ENCENDIDO No se produce Verifique que haya o se forma medicamento en el vaso poca niebla del Nebulizador Verifique que el Nebulizador no est da ado Verifique la posici n...

Страница 15: ...bulizador Manguera de Conexi n Pipeta Curva Filtros de Aire 5 Accesorios Opcionales Boquilla con ngulo Av os Juego de Adaptador en T Juego de Inhalador con Chupete para Beb s M scara para Ni os M scar...

Страница 16: ...16 NOTAS...

Отзывы: