3.4

 

User Sequence 

Clicking on the ‘User Sequence’ button in the main window of any model will open a new 
window – the User Switching sequence window (see 

Fig. 3.4.1

). This screen allows the user to 

run timed sequences of switching any of the switches in the model either individually or 
together, and run external programs synchronized with the switching sequence. 

 
 

3.4.1

 

User sequence screen buttons and indicators 

 

# Name

 

Description

 

Switching 

Set Name 

Shows the name of the sequence displayed. If the sequence is not saved this 
indicator will be blank. 

Switching 

Sequence 

The list of commands in the sequence with an arrow pointing to the current 
command. Double clicking on the state of a switch in a command will change 
its state. 

Switch states  

Shows the state of each switch in the command. Double click on a state to 
change it.  

Insert 

Add the command above the current command 

Add 

Add a command to end of sequence  

Count Limit 

Enables setting a maximum number of cycles for the ‘run continuously’ option 
– Need to enter a number or uncheck option before clicking on  ‘run 
continuously’ 

Time Limit 

Enables setting a maximum duration for the ‘run continuously’ option – Need to 
enter a value (in minutes) or uncheck option before clicking on  ‘run 
continuously’ 

Current Step 

Run current command and remain on the same step 

Continuously 

Run all commands in the sequence, in a continuous loop until stopped by user 
or reach specified limit (if limit is set) 

10 

Stop 

Stop the continuous run loop of all commands in sequence 

11 

Back to Main 

Return to the initial screen of the model 

12 

View Switches 

When selected opens a graphical presentation window beside the user 
sequence window (

Fig 3.4.2

)  

13 

Remove Delete 

current 

command 

14 

Dwell ime 

The delay (in mSec) after toggling the switches to their new state before going 
to the next step (in ‘run continuously’). If no value is entered the program will 
proceed immediately to the next step 

15 

Exec Program 

If you wish to run an external program after changing the switches to their 
current state enter the file name here. File must be placed in 
C:\MCL_SwitchBox  

16 

Clear List 

Delete all commands in sequence 

17 

Recall 

Recall a previously saved sequence 

18 

Save 

Save the sequence in one of 99 sequence registers. Unless specifically named 
sequence will be saved as Seq-XX where XX is the register number. 

 
 
 
 
 
 
 
 
 

 

Содержание RC-1SP4T-A18

Страница 1: ...18 GHz Two SPDT switches Configurable as SPDT DPDT or SP3T USB 3SPDT A18 RC 3SPDT A18 DC to 18 GHz Three SPDT switches Configurable as SPDT DPDT 3PDT SP3T or SP4T USB 4SPDT A18 RC 4SPDT A18 DC to 18 G...

Страница 2: ...ponsibility for and will have no liability on account of any of the foregoing Accordingly this guide should be used as a guideline only Trademarks Microsoft Windows Visual Basic Visual C and Visual C...

Страница 3: ...ces 6 1 8 2 Intended Applications 7 1 8 3 Conformity 7 1 8 4 Supported Software environments 7 1 8 5 Included Accessories and Options 8 Chapter 2 Installation and Setup 9 14 2 1 Software Setup 9 2 2 I...

Страница 4: ...er sequence screen buttons and indicators 28 29 3 4 2 User sequence graphical switch presentation 29 30 3 5 Firmware update 31 32 3 6 Demo Mode 33 Figure 1 MINI CIRCUITS USB RF SPDT Switch Page 4 of 3...

Страница 5: ...lectrical shock WARNING 1 Ensure the switch matrix air vents are clear CAUTION 2 Do not attempt to switch signals of greater power than the switch is rated for in its datasheet 1 5 Introduction Mini C...

Страница 6: ...of 100 million switching cycles DC to 18GHz absorptive failsafe RF switches in break before make configuration Electromechanical switching Isolation 85 dB typ High power handling 10W SPDT 2W SP4T All...

Страница 7: ...nition for Human Interface Devices firmware rev 1 11 TCP IP The RC xxxxx A18 series models Ethernet communication complies with the specifications of the Transmission Control Protocol TCP and Internet...

Страница 8: ...arge When ordering select one power cord to be included at no extra charge When ordering select one power cord to be included at no extra charge Accessories Available RC 1SPDT A18 RC 2SPDT A18 RC 3SPD...

Страница 9: ...or e mail apps minicircuits com for North America or go to minicircuits com contact worldwide_ tech_support html for other regional numbers and addresses 2 1 1 First save all work in progress and clos...

Страница 10: ...d now appear To proceed click I Agree and the Continue button Figure 2 2 2 License agreement 2 2 3 The installation program will launch Click the OK button to continue Figure 2 2 3 Installation Progra...

Страница 11: ...pear This window allows you to select the program group under which the link for the switch controller program in the Start Menu will be created If you change the Program Group for this software be su...

Страница 12: ...1 24V connector to the switch matrix unit 24V power socket Connect USB cable between switch matrix unit USB port and computer USB port Note the USB indicator lights up Turn on the USB RC switch matrix...

Страница 13: ...cating data transmission Figure 2 3 3a switch matrix Ethernet control power up setup Figure 2 3 3b switch matrix power Ethernet control connections Connect to wall current using the supplied power cor...

Страница 14: ...cted to ensure proper operation of the unit 2 4 Controlling the Mini Circuits Switch Matrix Mini Circuits offers multiple methods of controlling our switch matrices You can Use the supplied windows pr...

Страница 15: ...The Mini Circuits RF USB Switch Controller icon should be waiting there for you Click on it and get started 3 1 2 The Switch Controller Startup screen will appear For USB click on the USB button for...

Страница 16: ...main screen Click on the Ethernet Config button shown in the figure below and the Ethernet configuration screen will appear Figure 3 1 5 Ethernet Config button on USB main screen 3 1 7 The Ethernet Co...

Страница 17: ...IP not available when DHCP is selected 8 Static Configuration When DHCP is not selected the User must specify the values below and will not be changed by the server 9 Telnet Port Port to be used for t...

Страница 18: ...4 To start the program go to the Start menu and select All Programs Mini Circuits RF USB Switch Controller default or go to the other destination address you selected earlier The Mini Circuits RF USB...

Страница 19: ...st of units found click on the Search button 2 The search function uses ports UDP 4950 and UDP 4951 for communication ensure your firewall allows access to these ports 3 2 6 After entering the IP addr...

Страница 20: ...d the placement of the RF cables shown in the configuration screen These preset configurations are currently available only via USB control for complex configurations with timing considerations or set...

Страница 21: ...A18 RC 2SPDT A18 as a SP3T switch Clicking on the Use as SP3T switch button in the main window will transfer you to a new window the SP3T configuration screen In order to use the switch box in this co...

Страница 22: ...require any external RF cables to work Clicking on the circled button will toggle both switches simultaneously as a single DPDT switch In order to return to the main window click on the Back to Main b...

Страница 23: ...drawing the button will change between COM 2 and COM 1 to indicate the current switch state or in the user sequence window opened by clicking on the user sequence button see section 3 4 Figure 3 3 3...

Страница 24: ...ction 3 3 2 2 or as two SP3T a SP4T and a SPDT a SP5T or a transfer switch with external RF cables as shown in he relevant screen same procedure as section 3 3 2 1 in addition to the default configura...

Страница 25: ...v A November 25 2014 M149081 R88277 File AN 49 002 A doc This document and its contents are the property of Mini Circuits Figure 3 3 4 1 USB 4SPDT A18 as SP5T 3 3 4 2 USB 4SPDT A18 RC 4SPDT A18 as a S...

Страница 26: ...ure 3 3 4 3 USB 4SPDT A18 as two SP3T B 3 3 5 USB 8SPDT A18 RC 8SPDT A18 This model has eight absorptive SPDT switches and can be configured in many different configurations in similar fashion to thos...

Страница 27: ...current switch state or in the user sequence window opened by clicking on the User Sequence button see section 3 4 Figure 3 3 6 USB 1SP4T A18 main window 3 3 7 Additional configurations not shown here...

Страница 28: ...uously option Need to enter a number or uncheck option before clicking on run continuously 7 Time Limit Enables setting a maximum duration for the run continuously option Need to enter a value in minu...

Страница 29: ...hes option This window shows the current state of all switches and allows you to illustrate multi switch setups by dragging one of the connector circles to another switch s connector for example 2 A t...

Страница 30: ...itching graphical switch view window 1SP4T Note Connections shown between switches need to be added by the user using external RF cables Page 30 of 33 AN 49 001 Rev A November 25 2014 M149081 R88277 F...

Страница 31: ...s being updated may cause the firmware to be corrupted It is therefore recommended to only update the firmware while both the switch matrix and the computer are connected to an Uninterruptable Power S...

Страница 32: ...dow 3 5 5 The selected file will be installed in the switch matrix the process will take up to a minute Figure 3 5 6 Firmware Progress Bar Window 3 5 6 After the firmware has updated an alert will app...

Страница 33: ...Demo mode selection screen 3 6 3 The main screen of the model selected will appear with all options available for the model selected however they are simulated with no communication to any unit conne...

Отзывы: