16
TEST METHODS
PCB-001-388
REVISION A (09/2017)
Expected Results
Below is the 640Hz measurement, when tes ng the PCB the waveform displayed should look very similar to this.
If it does not, something is wrong. Check connec ons & seMngs, if they are correct there is a fault condi on..
In order to pass this test the waveform measured will have to meet certain condi ons. These condi ons are
listed below…
•
Peak-Peak Voltage measured must be higher than 40v ±5v
•
Waveform frequency measured must be approximately 640Hz ±5Hz
If the values measured fulfil these requirements move on to the next test.
Voltage / Division
SeMng
Peak-Peak Voltage
Measurement
Time Base SeMng
Waveform
Frequency
PAGE 14