76
The communication operation is made only in the Measurement mode. During the modes other than the
Measurement mode, Error command is sent.
No response in the stand-by condition.
The flow control is not performed in the CSD-401.
CTS/RTS signal is not applied.
The X flow control is not performed.
The communication operation is a type of dialogue.
12-3-2. Selected output in the RS-232C stream mode and in synchronous with print sign
The output is of RS-232C is selected with the set of Function F-41.
The output of RS-232C is selected from [Gross value], [Net value] and [Load display data with state].
[Gross value] is selected as a default.
Setting Function F-41 becomes effective when the Function F-39 = [0] and at the same time the Function F-40 is
set as [1] or [2].
12-3-3. Specifications for RS-232C communication
With the set of Function F-42, select the specifications for RS-232C communication.
Function Nos.
Set value
Contents
F-42
00000
~ 13121
0 0 0
0
0
Data bit length
0 : 7 bit, 1 : 8 bit
Parity bit
0 : No Parity, 1 : Even Parity
2 : Odd Parity
Stop bit
0 : 1 bit, 1 : 2 bit
Baud rate
0 : 1 200 bps, 1 : 2 400 bps
2 : 4 800 bps, 3 : 9 600 bps
Terminator
0 : CR, 1 : CR
+
LF
[13020] is set as a default.
12-3-4. Set of address for RS-232C
The address is fixed to [00].
12-3-5. Yes/No of decimal point of RS-232C sending data
With the set of Function F-46, yes or no of decimal point of sending data of RS-232C shall be selected.
[No decimal point] is selected as a default.