101
(2) Specifications for RS-422/485 communication
Selec the specificatios forRS-422/485 with the set of Function F-42.
Function No.
Set value
Contents
F-42
00000
~ 13121
0
0
0
0
0
Data bit length
0: 7 bit
、
1: 8 bit
Parity bit
0: No parity
1: Even parity
2: Odd parity
Stop bit
0: 1 bit
、
1: 2 bit
Baud rate
0: 1 200 bps,1: 2 400 bps
2: 4 800 bps,3: 9 600 bps
Terminator
0: CR,1: CR
+
LF
[13020] is set as a default.
(3) Address setting for RS-422/485
With the set of Function F-43, address setting for RS-422/485 can be made.
Setting range: 00 ~ 31
[00] is set as a default.
(4) Change of RS-422/485
With the set of Function F-44, change of RS-422 and RS-485 can be preformed.
[RS-422] is set as a default.
(5) Delay time of sending back data of RS-485
After sending back from the Host side, you can delay the returning data from the CSD-401 side in
the case of sending terminal from the Host side becomes low impedance.
With the setting of F-45, you can set the delay time of sending back data of RS-485.
Setting range: 0 ~ 9 Unit : 0.1 s
[1] is set as a default.
(6) Yes/No of decimal point of sending data of RS-422/485
With the setting of F-46, presence of decimal point for RS-422/485 send data is selected.
[No decimal point] is selected as a default.