2.2.3
Plug-in cards
Product
Description
Position
PR 5900/04
2 x RS
‑
485 serial inter-
faces
The interface can be conigured by software.
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
PR 5900/07
1 analog input
1 analog output
Analog input:
internal 14 bits binary = 20,000 counts, @
e.g. 0…20 mA/0…10 V
Analog output: internal 16 bits =
65,536 counts, resolution of 20,000 @
20 mA
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
PR 5900/10 (W1)
Weighing electronics
Internal weighing electronics for connecting
load cells or weighing platforms in non-Ex
areas.
A maximum of two internal weighing electro-
nics units can be inserted.
For further information, refer to the PR 5900
installation manual.
WP A and/or
WP B
PR 5900/10 (WE1)
Weighing electronics
with Ex approval
Internal weighing electronics for connecting
load cells or weighing platforms in Ex areas.
A maximum of one internal weighing electro-
nics unit can be inserted.
For further information, see Option WE1 ad-
ditional information.
WP A
PR 5900/12
4 digital inputs
4 digital outputs
4 passive opto-decoupled inputs
4 relay outputs with potential-free change-
over contacts
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
PR 5900/13
4 digital inputs
4 digital outputs
4 active opto-decoupled inputs
4 relay outputs with potential-free change-
over contacts
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
PR 5900/17
6 digital inputs
8 digital outputs
6 passive opto-decoupled inputs
8 passive opto-decoupled outputs
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
PR 5900/32
2 RS
‑
232 serial interfa-
ces
The interface can be conigured by software.
For further information, refer to the PR 5900
installation manual.
Option
‑
1 and/or
Option
‑
2
2 Overview
Phase PR 5900/81
Minebea Intec
EN-7
Содержание Maxxis 5 Phase PR 5900/81
Страница 79: ...8 9 Freely assigned ranges Weighing point A Weighing point B 8 SPM Phase PR 5900 81 Minebea Intec EN 77...
Страница 80: ...from weighing point independently Phase PR 5900 81 8 SPM EN 78 Minebea Intec...
Страница 81: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 79...
Страница 82: ...from weighing point independently Phase PR 5900 81 8 SPM EN 80 Minebea Intec...
Страница 83: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 81...
Страница 84: ...from weighing point independently Phase PR 5900 81 8 SPM EN 82 Minebea Intec...
Страница 85: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 83...
Страница 86: ...from weighing point independently Phase PR 5900 81 8 SPM EN 84 Minebea Intec...
Страница 87: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 85...
Страница 88: ...from weighing point independently Phase PR 5900 81 8 SPM EN 86 Minebea Intec...
Страница 89: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 87...
Страница 90: ...from weighing point independently Phase PR 5900 81 8 SPM EN 88 Minebea Intec...
Страница 91: ...from weighing point independently 8 SPM Phase PR 5900 81 Minebea Intec EN 89...
Страница 92: ...from weighing point independently Phase PR 5900 81 8 SPM EN 90 Minebea Intec...