36
Troubleshooting
Diagnostic LEDs
Power On
The POWER ON LED lights when power is applied to the
drive and the plug-in card is connected properly.
Fault
The FAULT LED lights in any of the following conditions:
1. The hall sensors are miswired, not operating properly, not
properly nulled, or draw current in excess of 20 mA..
2. The drive reaches its peak phase current limit.
3. The drive has insufficient DC input power.
4. The enable switch is closed (drive is disabled).
POWER ON
FAULT
Figure 15. Diagnostic LED Location
250-0288.qxd 6/9/00 1:05 PM Page 36