28
Calibration
MIN SPD
The MIN SPD setting determines the motor speed when the speed
adjust potentiometer is turned full CCW. It is factory set to zero
speed.
To calibrate, turn the speed adjust potentiometer full CCW. To set
the minimum speed to zero, rotate the MIN SPD trimpot CCW
until the motor has stopped. To set a minimum speed higher than
zero, rotate the MIN SPD trimpot CW until the motor is running
at the desired minimum speed.
MAX SPD
The MAX SPD setting determines the motor speed when the
speed adjust potentiometer is turned full CW. It is factory set for
maximum rated speed.
To calibrate, set the MAX SPD trimpot full CCW. Turn the speed
adjust potentiometer full CW. Adjust the MAX SPD trimpot until
the desired maximum motor speed is reached.
Note: Check the MIN SPD and MAX SPD adjustments after
recalibrating to verify that the motor runs at the desired minimum
and maximum speed.