3-32
Setting radiator pump
On UJF-3042 and UJF-3042FX, if the noise of the cooling pump for LED UV unit become louder after updating
the firmware to the version 3.10 or later, change the setting as follows. (Supported from the firmware ver.3.10)
1
Press the
key in the local mode.
2
Press the [MACHINE SET] by pressing the
or
key, and press the
key.
3
Select the [RADIATOR PUMP] by pressing the
or
key, and press the
key.
4
The current pump type is displayed.
5
Select the [Type B] by pressing the
or
key, and press the
key.
6
Press the
key several times to end the setting.
< L O C A L >
FUNCTION
F U N C T I O N
M A C H I N E S E T
< E N T >
ENTER
M A C H I N E S E T
R A D I A T O R P U M P
< e n t >
ENTER
M A C H I N E S E T
P U M P
: T y p e
A
M A C H I N E S E T
P U M P
: T y p e
B
ENTER
END