2-26
Chapter 2 Basic Operation
6
Exit REMOTE mode.
(1)
Touch the
button.
The status changes from [WAITING] to [MAINTE].
When you do not control the color
fixation device from the printer
1
Turn on the main power supply of color
fixation device.
2
Start LOCAL mode.
(1)
Touch the
button.
The status changes from [MAINTE] to
[WAITING].
3
Turn on heater.
(1)
Touch the
button.
The operation screen is displayed.
(2)
Touch the
of the [HEATER].
The heater turns ON and the status changes
from [WAITING] to [HEATING].
You can go back to the previous screen by pressing
button.
4
Start printing.
• When the furnace temperature stabilizes at the
set temperature, the status changes from
[HEATING] to [READY].
(1)
Adjust the opening at the aperture
plate.(
(2)
Send print data from computer to printer.
Printing will start.
5
Turn OFF heater.
(1)
When printing is completed, touch the
button.
The operation screen is displayed.
(2)
Touch the
of the [HEATER].
The heater turns off and the status changes
from [READY] to [COOLING].
You can go back to the previous screen by pressing
button.
• When the furnace temperature falls below 60
degree C, the status changes to [COOLING] →
[WAITING].
6
Exit LOCAL mode.
(1)
Touch the
button.
The status changes from [WAITING] to
[MAINTE].
25.0
MAINTE
180.0
WAITING
HEATING
• If you leave the heater on without starting printing,
the heater will turn off automatically.
• For the time to turn off the heater, refer to
READY
COOLING
59.0
WAITING
180.0
Содержание Tx500P-3200DS
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http mimaki com Original instructions D203118 13 ...
Страница 30: ...1 16 Chapter 1 Before Use ...
Страница 126: ...4 30 Chapter 4 Maintenance ...
Страница 148: ...5 22 Chapter 5 Troubleshooting ...
Страница 154: ...Chapter 6 Appendix 6 6 ...
Страница 156: ... 2016 MIMAKI ENGINEERING CO LTD MM FW 2 00 ...