- 5.9 -
Regular wiping function [INT.WIPING]
In case plotting has set at HIGH range (Transferring printing), spray, ink blot, or nozzle-clogging
may happen.
It is caused by ink drops which flow up and adhere to the head surface by gap between the head and
the printing surface.
This function enables to wipe off condensed ink as wiping the nozzle at intervals during plotting.
•
This function is available to set for the head at HIGH range ONLY. (
page 2-6)
When setting Low range for head, it perform as OFF setting constantly and also doesn’t appear
on the menu.
STEP
1.
Push the [FUNCTION] key on the LOCAL mode.
2.
Select the [MAINTENANCE] pushing the [ ] or
[ ] key.
3.
Push the [ENTER] key.
Display the [STATION].
4.
Select the [INT.WIPING] pushing the [ ] or [ ]
key.
5.
Push the [ENTER] key.
6.
Select the [ON/OFF] pushing the [ ] or [ ] key.
7.
Push the [ENTER] key.
When selecting “OFF”, to step10.
8.
Enter the number of the scanning pushing the
[ ] or [ ] key. (10-9990 scan)
• The initial value of SCAN COUNT is 100.
Alter the setting value according to the status of use.
9.
Push the [ENTER] key.
10. Push the [END] key twice.
The menu returns to the LOCAL mode.
FUNCTION
SETUP
< ENT >
FUNCTION
MAINTENANCE
< ent >
MAINTENANCE
STATION
< ent >
MAINTENANCE
INT.WIPING
< ent >
INT.WIPING
RENEW
: OFF
: ON
INT.WIPING
SCAN COUNT
= 100
<LOCAL>
TWICE