– 3.21 –
Alignment of MARK SENSOR
The offset value of the cutter and the mark sensor can be adjusted.
Set the sheet on which the register mark is printed.
Setting Procedure
1) Install a cutter in the tool holder.
2) Confirm the plotter is in the local mode.
3) Press the [FUNCTION] key.
4) Select [MARK SENSOR] by pressing the jog
key [ ] [ ].
5) Press the [ENTER/HOLD] key.
6) Select [SENSOR OFS] by pressing the jog key
[ ] [ ].
7) Press the [ENTER/HOLD] key.
After detecting the register mark (one point), five additional
lines are cut every 0.2 mm on the center line and on both
sides of the center line of the detected register mark.
DATA CLEAR <ENT>
MARK sensor <ENT>
SENSOR CHK <ent>
A = 0.0 B = 0.0
CT1 020 050 0.30
SENSOR OFS <ent>
Misaligned by +0.2 mm from the enter
line of the register mark (---) in the A
and the B direction.
A direction
B direction
FUNCTION