Miller SRL2-M Series
Rodless Cylinders
10
Operating Range
(1) M0V5, M0H5, M2V5, M2H5, M3V5, M3H5, M5V5, M5H5: The
operating range is the distance, when the piston moves, between
one position where the switch first turns on and the other position in
the same direction where it turns off. The mid-point in the operating
range is the most sensitive position and the switch should be
mounted at that location.
(2) Proximity switches with two-color indicator, M2WV5, M3WV5:
The operating range is within the red-green-red lights on. The green
light shows the best mounting range.
Hysteresis
Hysteresis is the distance, when the piston moves, between one
position where the switch first turns on and the other position in the
opposite direction where it turns off. Switches should not be located
in this area.
Operating Range, Hysteresis
Bore
Operating Range (in)
Hysteresis (in)
Size
Proximity Switch
Reed Switch
Proximity Switch
Reed Switch
(mm)
M2V5, M2H5, M3V5, M3H5
M2WV5, M3WV5
M0V5, M0H5, M5V5, M5H5
M2V5, M2H5, M3V5, M3H5
M2WV5, M3WV5
M0V5, M0H5, M5V5, M5H5
16
.157 - .512
.157 - .472
.118 - .433
.060
.040
.120
20
.157 - .512
.157 - .472
.118 - .433
25
.374 - .610
.354 - .551
.335 - .531
32
.295 - .591
.315 - .551
.276 - .531
40
.453 - .689
.394 - .650
.394 - .630
.080
.060
.140
50
.650 - .945
.551 - .827
.571 - .846
63
.630 - .945
.551 - .827
.551 - .846
Vertical (V) Switches
Horizontal (H) Switches
Movement and Replacement of Switches, and Mounting and Removal of Lead Wire Holder
Moving Switches
Loosen the flat head screw on the switch
fixture. Move the switch body and fixture
along the cylinder tube to the desired
location.Tighten the flat head screw.
Replacing Switches
Loosen the flat head screw and slide the
switch from under the fixture. Do not
remove the fixture. Slide the new switch
under the fixture in the desired location
and tighten the flat head screw to a
torque value of 4.5-6 in. lbs.
Mounting Lead Wire Holder
Removing Lead Wire Holder
Push lead wire
holder with your
thumb and snap
it into place.
Insert a screw-
driver between the
cylinder tube and
the lead wire holder
and turn it to
remove the holder.
Hysteresis
Hysteresis
Operating Range
Operating Range
Green best mounting range
Red
Red
Green
.34
.43(.39)
.49(.45)
.25
.25
.34
.55
.15
.43
.22
.22
.39
1.04
.35
.15
.39
.93
.23
( ) Brackets indicate dimension for bi-color switch