OM-222 166 Page 31
Soak Function
When type is set to Soak, the following screen appears on the display:
Mode.......: Custom Program
Segment....: 1
Type.......:>Soak
Soak Time..: 00:01:00
Custom Program Screen
Use the Cursor
button to move the cursor to the Soak Time position and use the Increase
or De-
crease
button to set the desired value.
When the cursor is in the Soak Time position, pressing the Cursor
button again automatically advances the
program to the next segment number.
End Function
When type is set to End, the following screen appears on the display:
Mode.......: Custom Program
Segment....:> 2
Type.......: End
Control TC.: 1
Custom Program Screen
The only changeable parameter in the End segment is selecting the number of thermocouples. Use the Cursor
button to move the cursor to the Control TC position. Press the Increase
or Decrease
but-
ton to select the number of control thermocouples to be used for the program. Selections are as follows: 1, 1,2,
1,2,3, or 1,2,3,4. TC1
MUST
always be a control thermocouple. TC2 thru TC4 can be used for controlling or
monitoring. When a thermocouple is selected as control, the LED adjacent to the seven-segment display
illuminates.
A custom program can contain up to 10 segments. To view Program parameters, position the cursor at segment
and use the Increase
or Decrease
button to advance through the segment numbers until the End
segment. When a segment number is changed, appropriate segment parameter information appears on the dis-
play.