OM-222 166 Page 27
The minimum and maximum temperature settings for preheat are 0 and 1000
F
(
−
18 and 538
C). The minimum and maximum soak times are 0 and 1000 hours.
When the system is utilizing air-cooled blankets, the maximum temperature
setting is 400
F (204
C). If the program setting is above 400
F (204
C), the
following screen will appear on the LCD display when the Run button is pressed:
NOTE
Maximum Temperature Message Screen
Cannot enter Run mode
Programmed temperature settings
exceed air cooled limits
(400
_
F, 204
_
C)
6-4-1-2. Bake-Out
The bake-out process allows the operator to program a temperature and soak time as well as a cooling rate from
bake-out if desired. When this process is selected, the following screen appears on the display:
Mode......: Bake
−
Out
Control TC:>1
Soak Temp.: 600 Soak Time: 01:00:00
Cool Temp.: 200 Cool Rate: 600
_
/Hr
Bake-Out Screen
The default position of the cursor is next to Control TC. Press the Increase
or Decrease
button to
select the number of control thermocouples to be used for the program. Selections are as follows: 1, 1,2, 1,2,3, or
1,2,3,4. TC1
MUST
always be a control thermocouple. TC2 thru TC4 can be used for controlling or monitoring.
When a thermocouple is selected as control, the LED adjacent to the seven-segment display illuminates.
Use the Cursor
button to move the cursor to the desired selection (Soak Temperature, Soak Time, Cool
Temperature, or Cool Rate), and press the Increase
or Decrease
button to change the value to the
desired setting.
The minimum and maximum soak temperature settings for bake-out are 0 and
1000
F(
−
18 and 538
C). The minimum and maximum soak times are 0 and 1000
hours. The minimum and maximum cool rates are 10 and 9999
/hr. When the
system is utilizing air-cooled blankets, the maximum temperature setting is 400
F(204
C). If the program setting is above 400
F (204
C), the following screen will
appear on the LCD display when the Run button is pressed: