MAINTENANCE &TROUBLESHOOTING
8-1. Routine Maintenance
!
Disconnect power before maintaining.
Maintain more often during severe conditions.
= Check
= Change
= Clean
= Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
Damaged Or Unreadable
Labels
Repair Or Replace Cracked
Weld Cable
Clean And Tighten Weld
Terminals
Check Gun Cable
Every
6
Months
OR
Inside Unit
Clean Drive Rolls
Apply Light Coat Of Oil Or
Grease To Drive Motor Shaft
8-2. Changing Drive Roll and Wire Inlet Guide
1
Securing Screw
2
Inlet Wire Guide
Loosen screw. Slide tip as close to
drive rolls as possible without
touching. Tighten screw.
3
Drive Roll
The drive roll consists of two
different sized grooves. The
stamped markings on the end
surface of the drive roll refers to the
groove on the opposite side of the
drive roll. The groove closest to the
motor shaft is the proper groove to
Drive Roll Securing Nut
Turn nut one click to secure drive
roll.
Tools Needed:
7/16 in.
1
2
3
4
907728
8-3. Overheating
Thermistors RT1, RT2, and the thermistors contained within the inverter module PM1 protect the unit from damage due to overheating. If the output
diode heatsink, output inductor L2, and/or inverter module PM1 get too hot, they command the weld controller to disable the output. The fan keeps
running to cool the unit. Wait several minutes before trying to weld.