A complete Parts List is available at www.MillerWelds.com
OM-279299 Page 36
6-6. Setting Crater Time
1
Left Knob
2
Right Knob
3
Home Button
The crater setting is the amount of time the
welding arc stays on after the welding gun
trigger is released. This feature is used to
fill the void or “crater” at the end of the
weld.
In the Setup menu, rotate the left knob to
highlight
Crater
, and rotate the right knob
to select
Manual
.
The following Crater variables can be ad-
justed:
Crater Time
: Time range is 0.1 to 5 sec-
onds.
Crater Voltage
(MIG settings) or
Arc
Length
(Pulse settings): Voltage range is
10 to 32 volts. Arc length range is 0 to 99.
Crater Wire Feed Speed
: Wire feed
speed range is 50 to 800 ipm.
Crater Delay
: This setting is for spot or
stitch welding without crater fill if the arc
time is less than the set time. Time range
is 0 to 5 seconds. (If crater delay is set for
2 seconds, weld operation will not go into
crater if gun trigger is released before 2
seconds.)
1
2
3
297061-D