OM-251958 Page 10
3-5. Environmental Specifications
A. IP Rating
IP Rating
IP22S
This equipment is designed for indoor use and is not intended to be used or stored outside.
IP22S 2014
−
06
B. Temperature Specifications
Operating Temperature Range*
Storage/Transportation Temperature Range
−
10 to 40
°
C (14 to 104
°
F)
*Output is derated at temperatures above 40
°
C (104
°
F).
−
20 to 55
°
C (
−
4 to 131
°
F)
Temp_2016- 07
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC61000-3-11 and IEC 61000
−
3
−
12 and can be connected to public low-voltage systems provided that the public
low-voltage system impedance Z
max
at the point of common coupling is less than __m
W
(or the short
−
circuit power S
sc
is greater than __VA).
It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that
the system impedance complies with the impedance restrictions.
ce-emc 1 2014-07
Notes
Содержание MigMatic 300
Страница 21: ...OM 251958 Page 15 Notes...
Страница 47: ...OM 251958 Page 41 956142846 B Figure 7 2 Circuit Diagram for Migmatic 300 400 VAC...
Страница 48: ...OM 251958 Page 42 956142852 B Figure 7 3 Circuit Diagram for Migmatic 380 230 400 VAC...
Страница 49: ...OM 251958 Page 43 956142848 B Figure 7 4 Circuit Diagram for Migmatic 380 400 VAC...
Страница 50: ...OM 251958 Page 44 956142851 C Figure 7 5 Circuit Diagram for Migmatic 300 DX 230 400 VAC...
Страница 51: ...OM 251958 Page 45 956142847 C Figure 7 6 Circuit Diagram for Migmatic 300 DX 400 VAC...
Страница 52: ...OM 251958 Page 46 956142853 C Figure 7 7 Circuit Diagram for Migmatic 380 DX 230 400 VAC...
Страница 53: ...OM 251958 Page 47 956142849 C Figure 7 8 Circuit Diagram for Migmatic 380 DX 400 VAC...