5-12. Spot Time Control (Reconfigured RMT 2T HOLD Output Selection)
SPO
1.0
1
3
1
Spot Time Meter Display
Select Spot function according to
Section 6-3G.
2
Amperage Switch Pad
3
Encoder Control
Set spot parameters as follows:
Press Amperage switch pad once
(meter A LED turns on) and turn En-
coder to set spot amperage. Press
Amperage switch pad again, (meter
S LED lights) and turn Encoder to
set spot time (.1
−
25 seconds). Fac-
tory default setting is 1 second.
Application:
To provide a timed
weld. Used for tacking, and thin
sheet joining.
2
5-13. Factory Parameter Defaults And Range And Resolution
Parameter
Default
Range And Resolution
PROCESS
* Stick OCV
TIG HF Impulse
Low OCV
TIG HF Impulse / TIG Lift / Stick
Low OCV / Normal OCV
*Stick Stuck Check
ScI (On)
ScI (On) / Sc0 (Off)
OUTPUT
RMT 2T
1
RMT STD
2T
RMT STD / RMT 2T / ON
RMT 2T can be reconfigured for: 2T / 4T / Mini Logic
/ 4T Momentary / Spot (see Section 6-3)
A MAIN / PEAK
DC TIG
DC STICK
150 A
110 A
1
−
200 Amps
1
−
200 Amps
Spot Time
**Weld Time
1.0 S
0 S
0.1
−
25.0 Seconds
Dual Range And Resolution
0.0
−
99.9 / 100
−
999 Seconds
PULSER
PPS
PEAK t
BKGND A
Off
100 Hz
40%
25%
ON / OFF
Dual Range And Resolution
0.1
−
9.9 / 10
−
500 Hertz
5
−
95 Percent
5
−
95 Percent
*Meter “PPP” Display
−−−
(Off)
−−−
(Off) / PPPP (On)
SEQUENCER
INITIAL A
**Initial Time
INITIAL SLOPE t
FINAL SLOPE t
FINAL A
**Final Time
20 A
0 S
0 S
0 S
5 A
0 S
1
−
200 Amps
0.0
−
25.0 Seconds
0.0
−
25.0 Seconds
0.0
−
25.0 Seconds
1
−
200 Amps
0.0
−
25.0 Seconds