OM-2226 Page 54
SECTION 7
−
MAINTENANCE AND TROUBLESHOOTING
7-1. Routine Maintenance
.
Maintain more often during severe conditions.
!
Disconnect power before maintaining.
A. Welding Power Source
n
= Check
Z
= Change
~
= Clean
Δ
= Repair
l
= Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
nl
Labels
n
l
Gas Hoses
Every
3
Months
n
Δ
l
Cables And Cords
Every
6
Months
~
:Durning heavy service, clean monthly.
!
Do not remove case when
blowing out inside of unit
(see Section 7-2) .
B. Optional Cooler
n
= Check
Z
= Change
~
= Clean
Δ
= Repair
l
= Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
~
Coolant Strainer,
durning heavy service,
clean more frequently.
~
Blow out heat exchanger fins.
n
Check coolant level. Top off with
distilled or deionized water if necessary.
Every
6
Months
nl
Hoses
nl
Labels
Every
12
Months
Z
Replace coolant.