OM-2226 Page 32
5-8. Output Control
1
1
Output Control
Press switch pad until desired parameter
LED is illuminated.
RMT STD (Remote Standard)
Application:
Use Remote Trigger (Stan-
dard) when the operator desires to use a
foot pedal or finger amperage control (see
Section 6-3A).
.
When a foot or finger remote current
control is connected to the welding
power source, initial amps, initial
slope, final slope, and final amps are
controlled at the remote control, not at
the welding power source.
.
If On/Off only type trigger is used, it
must be a maintained switch. All Se-
quencer functions become active, and
must be set by the operator.
RMT 2T HOLD
Application:
Use Remote Trigger Hold
(2T) when long extended welds are made.
Remote Trigger Hold (2T) can help to re-
duce operator fatigue.
If a foot or finger current control is con-
nected to the welding power source, only
trigger input is functional (see Section
6-3B).
.
This switch function can be reconfi-
gured for 4T, 4T Momentary, Mini Log-
ic, or Spot control See Section 6-3)
ON
Output will energize two seconds after be-
ing selected.
Application:
Use Output On for Stick
(SMAW) welding, or for Lift-Arc without the
use of a remote control (see Section
6-3H).