OM-403 Page 11
SECTION 4 – OPERATING WELDING GENERATOR
4-1.
Front Panel Controls
Ref. ST-178 079-A
5
2
3
1
Engine Control Switch
Use switch to start engine, select speed, and
stop engine. In Run/Idle position, engine
runs at idle speed at no load, and weld/power
speed under load. In Run position, engine
runs at weld/power speed.
.
Place switch in Run position to operate
most GMAW equipment.
2
Engine Choke Control
Use control to change engine air-fuel mix.
To Start: pull out choke and turn Engine
Control switch to Start position. Release
switch and slowly push choke in when en-
gine starts. Do not crank engine if engine is
still turning.
To Stop: turn Engine Control switch to Off
position.
3
Weld Process Selector Switch
Use switch to select type of weld output.
Use a positive (+) position for Direct Current
Electrode Positive (DCEP) and a negative
(–) position for Direct Current Electrode Neg-
ative. Use AC position for alternating cur-
rent.
4
Coarse Adjust Switch
Use switch to select weld amperage range
when Weld Process Selector switch is in
Stick/Tig position, or voltage range when
switch is in Wire position.
.
For best arc starts, use lowest amper-
age range possible.
5
Fine Adjust Control
Use control to select weld amperage (Stick/
Tig) or voltage (Wire) within the range se-
lected by the Coarse Adjust switch. Control
may be adjusted while welding. Weld output
would be 110 A DC based on control settings
shown (50% of 70 to 150 A).
6
Engine Hour Meter
1
6
4