Quick Setup Guide
9
Step 08.
Connect the thermocouple
temperature sensor(s).
Sensors MUST be placed properly to prevent
heating tool damage. One sensor is required for EACH
heating tool. Sensor can be contact or welded on.
a.
If insulation IS being used, place a sensor
under
the insulation
in direct contact with the workpiece
in the
center of the tool.
b.
If insulation IS NOT being used, place a sensor
under the center area of the heating tool
in direct contact with the workpiece.
c.
Place additional sensors on the workpiece
in accordance with project requirements.
d.
Connect all thermocouple temperature sensor
connector plugs to the thermocouple receptacle
on the side of the ArcReach Heater extension
cable.
e.
Minimum number of thermocouple temperature
sensors is one — maximum is six.
NOTE:
1. Workpiece
2. Preheat insulation
3. Air-cooled quick wrap
4. Thermocouple temperature sensor:
Route armored TC cables separate from
induction cables/leads to prevent interaction.
5. Weld joint
6. ArcReach Heater extension cable
7. Thermocouple receptacle
8. Thermocouple temperature sensor connector plugs
9. Thermocouple connection panel
8
7
5
4
2
3
2
4
3
1
6
8
Step 09.
Power on the XMT
®
350 FieldPro
™
with ArcReach welding power source
or ArcReach compatible engine drive.