Quick Setup Guide
5
Step 04.
Apply welded thermocouples
if they are being used.
Step 05.
Apply preheat insulation
(if required).
If using contact TC probes, skip to step 05.
Reference the chart below. Apply insulation on the workpiece
anywhere a heating tool will be placed.
Part Temp
½
"
Preheat Insulation Required
ºF
ºC
Quick Wrap
Air-Cooled Cable
122–302
50–150
—
—
302–392
150–200
—
1 Layer
392-482
200-250
1 Layer
1 Layer
482–600
250–315
1 Layer
2 Layers