Miller 301390 Скачать руководство пользователя страница 6

a. 

Secure preheat cover wrap around the air-cooled cable.  

 This does NOT act as a layer of insulation but protects  

 

     from jobsite abrasion and weld spatter. 

b. 

Put a piece of fiberglass tape or clearly identify the middle of  
the cable with the wrap on to make the cable wrap process  
more efficient. 

c. 

Locate the center of the heating cable.

d. 

Route the center of the cable over the top of the pipe, and pull it 
through underneath to start the first turn. Route the cable over the 
top of the pipe again, working toward the joint to start the second 
turn. If there is enough cable, a third wrap can be added by routing 
the center of the cable over the top of the pipe again.

e. 

Once the desired number of turns are applied, route the outer 
loose ends of the cable through the center loop a few times each 
(depending on the loop length) to bring the leads together. 

f. 

Twist the remainder of the leads together from the coil to the TC 
Extension Cable to cancel the magnetic field between them and 
minimize incidental heating of nearby metal objects.

ArcReach

®

 Heater

6

Step 06.

Apply the appropriate heating 

tool — either air-cooled cables 

or air-cooled quick wrap.

a. 

If insulation is being used, apply the heating tool 

over

 the insulation.

b. 

To decrease heating time, place the heating tool closer to the  
weld joint.

c. 

Insulation can be secured in place with a non-conductive strap  
or tape such as fiberglass reinforced tape. 

Do not use metal  

straps or wire. 

NOTE:

A typical air-cooled cable induction coil will have 2 – 3 turns on each side of the joint. Pipe diameters larger than 24" 
will usually require two separate heaters depending on target temperature and time-to-temp requirements.

If using TC probes, position them under the insulation (under the heating cable) in direct contact with the workpiece.

This is an example of a typical air-cooled coil on small-diameter pipe using a single heating cable.

Steps for proper

 

air-cooled 

cable application:

HAZARDOUS VOLTAGE; ELECTRIC SHOCK can kill.

Do not use wire or metal straps to secure cable. Instead, use

plastic cable ties, tape, or non-conductive straps to secure cable.

Do not hang cable on metal brackets, hangers, or other

mechanisms.

Stop using equipment if plug, receptacle, or cable is damaged.

Replace cable if braid, red jacket, or bare wire is visible.

Read and follow all labels and the Owner’s Manual carefully.

DANGER

Do Not Remove, Destroy, Or Cover This Label.

Содержание 301390

Страница 1: ...Quick Setup Guide ARCREACH HEATER...

Страница 2: ...ter System or a Power Source b ArcReach Heater c Extension Cable and Series Adapter d Thermocouples TCs e Insulation Fault Detection Magnet f Preheat Insulation g Air Cooled Quick Wraps h Air Cooled C...

Страница 3: ...me to both machines Work negative connectors Do not use worn damaged or repaired weld cables Only use 2 0 70 mm sq cables with a maximum length of 200 feet 61 m WARNING Step 01 Connect the ArcReach He...

Страница 4: ...cable to the Work cable plug on the ArcReach Heater extension cable b To connect plug align the key with the keyway insert its end into the receptacle and rotate the plug until tight c Use handle to p...

Страница 5: ...red If using contact TC probes skip to step 05 Reference the chart below Apply insulation on the workpiece anywhere a heating tool will be placed Part Temp Preheat Insulation Required F C Quick Wrap A...

Страница 6: ...either air cooled cables or air cooled quick wrap a If insulation is being used apply the heating tool over the insulation b To decrease heating time place the heating tool closer to the weld joint c...

Страница 7: ...portion of the air cooled quick wrap together and position the cinch clip as close to the workpiece as possible To prevent damage to the Quick Wrap do not pull on housing connectors item 3 or cable l...

Страница 8: ...material a Single tool Connect from A to B on the upper box b Two tools Connect one tool from A to A and the second tool from B to B NOTE 1 ArcReach Heater extension cable nameplate 2 Single tool wit...

Страница 9: ...ccordance with project requirements d Connect all thermocouple temperature sensor connector plugs to the thermocouple receptacle on the side of the ArcReach Heater extension cable e Minimum number of...

Страница 10: ...corded The main section shows readings for all connected thermocouples TCs If a control TC is not sending a reading the background of that TC turns red The information in the right panel depends on th...

Страница 11: ...d Select individual data files that you want to save using the Select button e Use the Save button to save the selected data files to USB Step 02 Set joint heating profile Option 1 Manual instruction...

Страница 12: ...ftware for loading heat temperature files and chart recording visit millerwelds com support software arcreach heater software 2019 Miller Electric Mfg LLC Miller the Miller logo The Power of Blue ArcR...

Отзывы: