Quick Setup Guide
7
If using TC probes, position them under the insulation (under the heating wrap) in direct contact with the workpiece.
a.
Place the air-cooled quick wrap on the workpiece around the insulation.
b.
Align the connector housings and fully engage the connector pins.
c.
Turn the latching handle to hold the connectors together.
d.
Hold the unused portion of the air-cooled quick wrap together and position the cinch clip as close to the workpiece
as possible. To prevent damage to the Quick Wrap, do not pull on housing connectors (item 3) or cable leads (item
7) during or after installation of cinch clip (item 5).
e.
Close the cinch clip to hold the leads together. Use the latch to secure the cinch clip in place.
Steps for proper
air-cooled quick wrap
cable application:
1. Workpiece
2. Air-cooled quick wrap
3. Housing connectors
4. Latching handle
5. Cinch clip
6. Cinch clip latch
5
4
1
3
2
4
5
5
5
5
6
6
6