OM-629 Page 15
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1.
Routine Maintenance
Y
Disconnect power before maintaining.
3 Months
Replace
unreadable
labels.
Repair or
replace cracked
weld cables.
Adjust
spark
gaps.
Clean and
tighten weld
connections.
Replace
cracked
parts.
6 Months
Blow out or
vacuum inside.
During heavy service,
clean monthly.
Or
5-2.
Adjusting Spark Gap
Ref. ST-801 481-A / Ref. S-0043
Y
Turn Off power before ad-
justing spark gap.
1
Tungsten End Of Point
Replace point if tungsten end dis-
appears; do not clean or dress
tungsten.
2
Spark Gap
Normal spark gap is 0.012 in (0.3
mm). If adjustment is needed, pro-
ceed as follows:
3
Adjustment Screw
Loosen screw. Place gauge of
proper thickness in spark gap.
4
Pressure Point
Apply slight pressure at point until
gauge is held firmly in gap. Tighten
screw. Replace wrapper.
Tools Needed:
1/4 in
5/32 in
1
4
3
2
0.012 in (0.3 mm)