OM-629 Page 11
3-3.
Remote 14 Connections
ST-800 293 / ST-145 666-C / ST-801 480
1
Remote 14 Receptacle
Use to make connection to remote
control device.
2
Remote 14 Plug
Use to make connection to welding
power source Remote 14
receptacle.
OR
1
2
3-4.
Remote 14 Receptacle Information
Pin*
Pin Information
A
24 volts ac.
B
Contact closure to A completes 24 volts ac contactor control circuit.
A
J
B
K
I
C
+10 volts dc output to remote control.
C
L
N
H
D
Remote control circuit common.
D
M
G
E
F
E
0 to +10 volts dc input command signal from remote control.
E
K
Circuit common
*The remaining pins are not used.
3-5.
Remote 14 Plug Information
Pin*
Pin Information
A
+15 volts dc input from welding power source.
A
J
B
Contact closure to A com15 volts dc contactor control circuit.
A
J
B
K
I
C
+10 volts dc input from welding power source.
C
L
N
H
D
Remote control circuit common.
D
M
G
E
F
E
0 to +10 volts dc command signal from remote control to welding power source.
K
Circuit common
*The remaining pins are not used.